NGS Troubleshooting


Star Trac 4000, 4010, 4020 Error Codes

DISPLAY READS POSSIBLE CAUSES ARE:
NO STO
(no stop key on power up)
• Disconnected remote stop switch.
• Shorted remote stop switch.
• Stuck or sticking stop switch.
• Faulty display board.
KEY DN
(key down on power up)
• Wrong key used when trying to access Test Mode.
• Face plate keys damaged.
• Faceplate keys shorted.
NO RPM • Disconnected or faulty RPM/Hall effect sensor.
• Misaligned RPM sensor.
• Flywheel abrading the RPM sensor cable.
• Dirty RPM sensor and disc (Optical sensor).
• RPM feedback loss (Optical sensor).
• Faulty MCB.
SP CNG
(abrupt speed change)
• Disconnected or faulty RPM/Hall effect sensor.
• Misaligned RPM sensor.
• Flywheel abrading the RPM sensor cable.
• Dirty RPM sensor and disc (Optical sensor).
• RPM feedback loss (Optical sensor).
• Faulty MCB.
• IR Comp adjustment.
EL STL, RNG, or LOST
(elevation stall or out of range)
• Blown elevation fuses.
• Faulty elevation motor.
• Faulty MCB.
• Faulty display cable.
• Elevation count not within range.
• Mechanical binding.
EL NOZ
(elevation can’t find 0%)
• Elevation count not within range.
• Faulty elevation motor.
• Faulty MCB.
• Faulty display cable.
• Blown elevation fuses.
• Mechanical binding.